Application Range | ||||
Pressure [MPa] | Temperature [°C] | Sliding speed[m/s] | Medium | |
Standard | 40 | -35 ... +120 | 1 | Mineral oil based hydraulic fluids, barely flammable hydraulic fluids, water, air and others. |
Material | |||
Standard Design | PU (Shore 90-95A) |
Standard and /or can fit the groove |
JB/ZQ 4264 GY2 |
Pressure | 160bar | 250bar | 400bar |
Max Gap E | E≤0.6mm | E≤0.5mm | E≤0.4mm |
D H9 | d h9 | H | L1 +0.2 | L2 +0.2 | R1≤ | C≥ |
20~28 | D-6 | 8 | 8.5 | 11.5 | 0.2 | 3 |
30~55 | D-8 | 10 | 11 | 12.5 | 0.2 | 3 |
55~160 | D-12 | 14 | 15 | 17 | 0.4 | 3.5 |
105~300 | D-16 | 18 | 19 | 21.5 | 0.8 | 5 |
320~650 | D-24 | 24 | 26 | 29 | 0.8 | 6.5 |